Institutional Repository of Coll Energy & Power Engn
Study on method for measuring the regurgitant volume of cardiac valve prostheses under unsteady-flow condition | |
Wei, Liejiang1; Li, Shaonian1![]() ![]() | |
2008-03-01 | |
发表期刊 | Journal of Information and Computational Science
![]() |
ISSN | 15487741 |
卷号 | 5期号:2页码:513-520 |
摘要 | This paper presented a new method for measuring regurgitant volume of Cardiac valve prostheses, that used unsteady flow instead of steady flow, deducted the elevation condition for application (ECA) of the method, established nonlinear differential equations of unsteady flow by Lagrange integral, studied it by numerical analysis, and analyzed the measurement error. The experimental results showed that the measuring precision is about 2.27%, if the ECA is satisfied and the ratio of cross sectional areas of valve and test tube is smaller than 3.422%. |
关键词 | Differential equations Errors Nonlinear equations Numerical methods Prosthetics Cardiac valve prosthesis Cross sectional area Flow condition Lagrange Measuring precision Nonlinear differential equation Regurgitant volume Test tube |
收录类别 | EI |
语种 | 英语 |
出版者 | Sun Yat-sen (Zhongshan) University |
EI入藏号 | 20084711727770 |
EI主题词 | Unsteady flow |
EI分类号 | 462.4 Prosthetics - 631.1 Fluid Flow, General - 921.2 Calculus - 921.6 Numerical Methods |
来源库 | Compendex |
分类代码 | 462.4 Prosthetics - 631.1 Fluid Flow, General - 921.2 Calculus - 921.6 Numerical Methods |
文献类型 | 期刊论文 |
条目标识符 | https://ir.lut.edu.cn/handle/2XXMBERH/111970 |
专题 | 能源与动力工程学院 科学技术处(军民融合领导小组办公室) |
作者单位 | 1.College of Fluid Power and Control, Lanzhou University of Technology, Lanzhou 730050, China; 2.Company of Medical Instrument, Lanzhou Flight and Control Instruments General Plant, Lanzhou 730070, China |
第一作者单位 | 兰州理工大学 |
第一作者的第一单位 | 兰州理工大学 |
推荐引用方式 GB/T 7714 | Wei, Liejiang,Li, Shaonian,Wei, Zhongying,et al. Study on method for measuring the regurgitant volume of cardiac valve prostheses under unsteady-flow condition[J]. Journal of Information and Computational Science,2008,5(2):513-520. |
APA | Wei, Liejiang,Li, Shaonian,Wei, Zhongying,&Ji, Hong.(2008).Study on method for measuring the regurgitant volume of cardiac valve prostheses under unsteady-flow condition.Journal of Information and Computational Science,5(2),513-520. |
MLA | Wei, Liejiang,et al."Study on method for measuring the regurgitant volume of cardiac valve prostheses under unsteady-flow condition".Journal of Information and Computational Science 5.2(2008):513-520. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。