Institutional Repository of Coll Elect & Informat Engn
Simulation study on dynamic response of doubly fed induction generators during system voltage sag caused by power grid faults | |
Wang, Xiao-Lan![]() | |
2010-08-01 | |
发表期刊 | Dianwang Jishu/Power System Technology
![]() |
ISSN | 10003673 |
卷号 | 34期号:8页码:170-175 |
摘要 | To research the dynamic response of wind power generation unit under certain grid voltage sag in depth, taking single doubly-fed induction generator (DFIGs) with capacity of 1. 5 MW as research object and referring to the standard of low-voltage ride through (LVRT) drifted by American Wind Energy Association (AMEN), by means of building different simulation models of grid voltage sag, the dynamic responses of terminal voltage, stator current, rotor current, active power output and reactive power output, voltage at DC side and electromagnetic torque during the fault are simulated respectively. Through comparing the variations of these variables under several typical faults, corresponding control strategies, which are available for reference to further research on control strategy based on the standard of LVRT, are investigated. |
关键词 | Dynamic response Electric fault currents Electric power generation Electric power transmission networks Reactive power Wind power Active power output American wind energy associations Doubly fed induction generator (DFIG) Doubly fed induction generators Electromagnetic torques Low-voltage ride-through Reactive power output Voltage sags |
收录类别 | EI |
语种 | 中文 |
出版者 | Power System Technology Press |
EI入藏号 | 20103413174689 |
EI主题词 | Asynchronous generators |
EI分类号 | 615.8 Wind Power (Before 1993, use code 611 ) - 701.1 Electricity: Basic Concepts and Phenomena - 705.2.1 AC Generators - 706.1.1 Electric Power Transmission |
来源库 | Compendex |
分类代码 | 615.8 Wind Power (Before 1993, use code 611 ) - 701.1 Electricity: Basic Concepts and Phenomena - 705.2.1 AC Generators - 706.1.1 Electric Power Transmission |
文献类型 | 期刊论文 |
条目标识符 | https://ir.lut.edu.cn/handle/2XXMBERH/111197 |
专题 | 电气工程与信息工程学院 |
作者单位 | School of Electrical and Information Engineering, Lanzhou University of Technology, Lanzhou 730050, Ganshu Province, China |
第一作者单位 | 兰州理工大学 |
第一作者的第一单位 | 兰州理工大学 |
推荐引用方式 GB/T 7714 | Wang, Xiao-Lan,Sun, Wan-Yi. Simulation study on dynamic response of doubly fed induction generators during system voltage sag caused by power grid faults[J]. Dianwang Jishu/Power System Technology,2010,34(8):170-175. |
APA | Wang, Xiao-Lan,&Sun, Wan-Yi.(2010).Simulation study on dynamic response of doubly fed induction generators during system voltage sag caused by power grid faults.Dianwang Jishu/Power System Technology,34(8),170-175. |
MLA | Wang, Xiao-Lan,et al."Simulation study on dynamic response of doubly fed induction generators during system voltage sag caused by power grid faults".Dianwang Jishu/Power System Technology 34.8(2010):170-175. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
查看访问统计 |
谷歌学术 |
谷歌学术中相似的文章 |
[Wang, Xiao-Lan]的文章 |
[Sun, Wan-Yi]的文章 |
百度学术 |
百度学术中相似的文章 |
[Wang, Xiao-Lan]的文章 |
[Sun, Wan-Yi]的文章 |
必应学术 |
必应学术中相似的文章 |
[Wang, Xiao-Lan]的文章 |
[Sun, Wan-Yi]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论