Experimental study on seismic behaviour of the outrigger truss-core wall spatial joints with peripheral CFST columns
Rui, Jia1; Xian, Wei1,2; Wang, Wen-Da1,2; Zhu, Yan-Peng1,2; Wang, Jing-Xuan1,2
2022-07
发表期刊STRUCTURES
ISSN2352-0124
卷号41页码:1014-1026
摘要To understand the feasibility and seismic behaviour of the outrigger truss-core wall joints with peripheral concrete-filled steel tubular (CFST) columns, this paper presented an experimental study on outrigger trussconcrete shear wall joints under quasi-static cyclic loading. Two joint specimens with various details, namely, the length of the shear wall, were tested and intensively compared. The failure mode, load versus displacement hysteretic curve, strain distribution, failure mechanism and the key indexes reflecting the seismic behaviours, i. e., strength degradation, stiffness degradation, ductility and energy dissipation capacity of joints were analysed, respectively. The results show that the failure process of joints can be divided into three stages, namely, stress stages of shear wall and outrigger truss, outrigger truss and concealed column system, and failure stage of truss system, and the energy consumption of joints mainly occurs in the second stage. The failure of the two joints are located at the connection of outrigger truss and concealed column in shear wall. The length of wall has limited influence on the peak bearing capacity of joints, and the concentrated load of chord and web members of outrigger truss is transferred to shear wall through concealed column connection. The reasonable transition of stiffness of the connection between the shear wall and the outrigger truss should be adopted in the joint design, and the increase of the distance from the concealed column to the edge of the shear wall is beneficial to improve the mechanical performance and ductility of joints. The average ductility factor of two tested joints under the positive and negative loading is 1.67. The average value of the equivalent viscous damping coefficient of tested joints is 0.23, which is 130% higher than that of reinforced concrete joints of 0.1. These indicate that the tested joint exhibits a superior seismic performance and energy dissipation capacity.
关键词Outrigger truss Seismic performance Failure mechanism Hysteresis curves Energy dissipation capacity
DOI10.1016/j.istruc.2022.05.066
收录类别SCIE ; EI
语种英语
WOS研究方向Engineering
WOS类目Engineering, Civil
WOS记录号WOS:000814561800004
出版者ELSEVIER SCIENCE INC
EI入藏号20232014108485
EI主题词Shear walls
EI分类号402 Buildings and Towers ; 408 Structural Design ; 408.2 Structural Members and Shapes ; 412 Concrete ; 484 Seismology ; 484.1 Earthquake Measurements and Analysis ; 484.3 Earthquake Resistance ; 525.3 Energy Utilization ; 525.4 Energy Losses (industrial and residential) ; 951 Materials Science ; 961 Systems Science
来源库WOS
引用统计
被引频次:1[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符https://ir.lut.edu.cn/handle/2XXMBERH/158869
专题土木工程学院
通讯作者Wang, Wen-Da
作者单位1.Lanzhou Univ Technol, Sch Civil Engn, Lanzhou 730050, Peoples R China;
2.Western Ctr Disaster Mitigat Civil Engn, Minist Educ, Lanzhou 730050, Peoples R China
第一作者单位兰州理工大学
通讯作者单位兰州理工大学
第一作者的第一单位兰州理工大学
推荐引用方式
GB/T 7714
Rui, Jia,Xian, Wei,Wang, Wen-Da,et al. Experimental study on seismic behaviour of the outrigger truss-core wall spatial joints with peripheral CFST columns[J]. STRUCTURES,2022,41:1014-1026.
APA Rui, Jia,Xian, Wei,Wang, Wen-Da,Zhu, Yan-Peng,&Wang, Jing-Xuan.(2022).Experimental study on seismic behaviour of the outrigger truss-core wall spatial joints with peripheral CFST columns.STRUCTURES,41,1014-1026.
MLA Rui, Jia,et al."Experimental study on seismic behaviour of the outrigger truss-core wall spatial joints with peripheral CFST columns".STRUCTURES 41(2022):1014-1026.
条目包含的文件
条目无相关文件。
个性服务
查看访问统计
谷歌学术
谷歌学术中相似的文章
[Rui, Jia]的文章
[Xian, Wei]的文章
[Wang, Wen-Da]的文章
百度学术
百度学术中相似的文章
[Rui, Jia]的文章
[Xian, Wei]的文章
[Wang, Wen-Da]的文章
必应学术
必应学术中相似的文章
[Rui, Jia]的文章
[Xian, Wei]的文章
[Wang, Wen-Da]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。