IR
Safety evaluation of bionic-muscle cable-driven lower limb rehabilitation robot system
Wang, Yan-Lin1,2; Wang, Ke-Yi1; Wang, Kui-Cheng1; Mo, Zong-Jun1; Wang, Lu-Ying1
2022
发表期刊Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science)
ISSN1008-973X
卷号56期号:1页码:168-177
摘要A bionic muscle cable model was given based on the Hill muscle model, and a bionic-muscle cable-driven lower limb rehabilitation robot (BM-CDLR) was introduced in order to analyze the safety evaluation method and index of BM-CDLR. The safety performance factors were defined based on the motion planning of the rigid motion branch and mechanical analysis of the BM-CDLR. The use safety evaluation index of the BM-CDLR was proposed by considering the motion tolerance of different patients and the volatility of the motion speed of the slider in the rigid motion branch chain. The rationality of the use safety evaluation method of the BM-CDLR was verified through case analysis. Copyright ©2022 Journal of Zhejiang University (Engineering Science). All rights reserved.
关键词Bionics Cables Motion planning Neuromuscular rehabilitation Robot programming Safety factor Bionic muscle cable Cable-driven Lower limbs rehabilitation robots Motion-planning Performance factors Safety evaluation methods Safety evaluations Safety performance Safety performance factor Use safety
DOI10.3785/j.issn.1008-973X.2022.01.019
收录类别EI
语种中文
出版者Zhejiang University
EI入藏号20220311487846
EI主题词Muscle
EI分类号461.1 Biomedical Engineering ; 461.2 Biological Materials and Tissue Engineering ; 461.5 Rehabilitation Engineering and Assistive Technology ; 723.1 Computer Programming ; 731.5 Robotics ; 914.1 Accidents and Accident Prevention
引用统计
文献类型期刊论文
条目标识符https://ir.lut.edu.cn/handle/2XXMBERH/157909
专题兰州理工大学
作者单位1.College of Mechanical and Electrical Engineering, Harbin Engineering University, Harbin; 150001, China;
2.School of Mechanical and Electrical Engineering, Lanzhou University of Technology, Lanzhou; 730050, China
第一作者单位兰州理工大学
推荐引用方式
GB/T 7714
Wang, Yan-Lin,Wang, Ke-Yi,Wang, Kui-Cheng,et al. Safety evaluation of bionic-muscle cable-driven lower limb rehabilitation robot system[J]. Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science),2022,56(1):168-177.
APA Wang, Yan-Lin,Wang, Ke-Yi,Wang, Kui-Cheng,Mo, Zong-Jun,&Wang, Lu-Ying.(2022).Safety evaluation of bionic-muscle cable-driven lower limb rehabilitation robot system.Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science),56(1),168-177.
MLA Wang, Yan-Lin,et al."Safety evaluation of bionic-muscle cable-driven lower limb rehabilitation robot system".Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science) 56.1(2022):168-177.
条目包含的文件
条目无相关文件。
个性服务
查看访问统计
谷歌学术
谷歌学术中相似的文章
[Wang, Yan-Lin]的文章
[Wang, Ke-Yi]的文章
[Wang, Kui-Cheng]的文章
百度学术
百度学术中相似的文章
[Wang, Yan-Lin]的文章
[Wang, Ke-Yi]的文章
[Wang, Kui-Cheng]的文章
必应学术
必应学术中相似的文章
[Wang, Yan-Lin]的文章
[Wang, Ke-Yi]的文章
[Wang, Kui-Cheng]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。