Optimization and verification of dynamic flow balance valve structure | |
Li, Shuxun1,2![]() ![]() | |
2021-07-30 | |
发表期刊 | Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology
![]() |
ISSN | 03676234 |
卷号 | 53期号:7页码:108-115 |
摘要 | Aiming at the problem of low flow control accuracy of the dynamic flow balance valve, based on the orifice flow and concentric annular gap flow equations, the spool opening profile was initially designed, and the pressure difference compensation coefficient factor correction method was proposed to optimize and modify the existing profile formula. Based on the large eddy simulation (LES) turbulence model, the flow control accuracy and flow accuracy error of the dynamic flow balance valve before and after optimization were studied by numerical simulation, the influence of the valve core opening profile on the pressure pulsation intensity was compared and analyzed, and a flow test bench was built to verify the proposed optimization method. The results show that the pressure difference compensation factor correction method to optimize the spool opening profile can effectively reduce the pressure pulsation intensity of the spool end face, and improve the flow control accuracy of the dynamic flow balance valve to 3.7%. The flow field simulation calculation and the experimental results basically coincide with the trend. © 2021, Editorial Board of Journal of Harbin Institute of Technology. All right reserved. |
关键词 | Electromagnetic wave attenuation Flow control Large eddy simulation Numerical methods Reels Turbulence models Compensation coefficients Compensation factor Control accuracy Correction method Flow field simulation Optimization method Pressure differences Pressure pulsation |
DOI | 10.11918/202006055 |
收录类别 | EI |
语种 | 中文 |
出版者 | Harbin Institute of Technology |
EI入藏号 | 20213410794136 |
EI主题词 | Pressure control |
EI分类号 | 631 Fluid Flow ; 691.2 Materials Handling Methods ; 711 Electromagnetic Waves ; 731.3 Specific Variables Control ; 921 Mathematics ; 921.6 Numerical Methods |
引用统计 | 无
|
文献类型 | 期刊论文 |
条目标识符 | https://ir.lut.edu.cn/handle/2XXMBERH/151076 |
专题 | 石油化工学院 土木工程学院 |
作者单位 | 1.College of Petrochemical Technology, Lanzhou University of Technology, Lanzhou; 730050, China; 2.Machinery Industry Pump and Special Valve Engineering Research Center, Lanzhou; 730050, China; 3.Zhejiang Dunan Valve CO., LTD., Zhuji; 311800, China |
第一作者单位 | 兰州理工大学 |
第一作者的第一单位 | 兰州理工大学 |
推荐引用方式 GB/T 7714 | Li, Shuxun,Wu, Hanlin,Li, Zhong,et al. Optimization and verification of dynamic flow balance valve structure[J]. Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology,2021,53(7):108-115. |
APA | Li, Shuxun,Wu, Hanlin,Li, Zhong,Shen, Henyun,&Ye, Chen.(2021).Optimization and verification of dynamic flow balance valve structure.Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology,53(7),108-115. |
MLA | Li, Shuxun,et al."Optimization and verification of dynamic flow balance valve structure".Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology 53.7(2021):108-115. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
查看访问统计 |
谷歌学术 |
谷歌学术中相似的文章 |
[Li, Shuxun]的文章 |
[Wu, Hanlin]的文章 |
[Li, Zhong]的文章 |
百度学术 |
百度学术中相似的文章 |
[Li, Shuxun]的文章 |
[Wu, Hanlin]的文章 |
[Li, Zhong]的文章 |
必应学术 |
必应学术中相似的文章 |
[Li, Shuxun]的文章 |
[Wu, Hanlin]的文章 |
[Li, Zhong]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论