摘要 | Charge detection quadrupole ion trap (QIT) mass spectrometry (MS) is an effective technique for high-speed mass analysis of micron-sized particles such as biological cells and aerosols. In this technique, the trap can be operated by scanning the frequency of the ac field under a low-vacuum condition. This paper describes a calibration method which involves determination of the points of ejection (qeject) of the individual particles to be analyzed how the ejection points vary with the pressure of buffer gas. Using NIST polystyrene size as the test samples, a mean ejection point of qeject = 0.952 is attained at the trap driving voltage amplitude of 1617 V, with He buffer gas pressure of 5.33 Pa, and a frequency scan rate of 70 Hz/s over the scan range of 450-100 Hz. The mean value (0.947) of qeject is measured without the buffer gas. The result indicates the buffer gas has an effect on the ejection point of particle in the trap. |
关键词 | Ions Mass spectrometry Quantum optics Buffer gas pressure Calibration method Driving voltages Individual particles Laser-induced acoustic desorptions Mass-to-charge ratio Micron-sized particles Quadrupole ion traps |
DOI | 10.3788/AOS200929S1.223 |
收录类别 | EI |
语种 | 中文 |
出版者 | Chinese Optical Society |
EI入藏号 | 20092812177206 |
EI主题词 | Particle size analysis |
EI分类号 | 741.1 Light/Optics - 801 Chemistry - 951 Materials Science |
来源库 | Compendex |
分类代码 | 741.1 Light/Optics - 801 Chemistry - 951 Materials Science |
引用统计 | 无
|
文献类型 | 期刊论文 |
条目标识符 | https://ir.lut.edu.cn/handle/2XXMBERH/111739 |
专题 | 兰州理工大学 |
作者单位 | 1.College of Math and Physics, Nanjing University of Information Science and Technology, Nanjing, Jiangsu 210044, China; 2.College of Technology and Engineering, Lanzhou University of Science and Technology, Lanzhou, Gansu 730050, China |
推荐引用方式 GB/T 7714 | Cui, Fenping,Pei, Shijin,Liu, Yanli,et al. Study on the frequency-scan quadrupole ion trap mass spectrometry[J]. Guangxue Xuebao/Acta Optica Sinica,2009,29(SUPPL.):223-225. |
APA | Cui, Fenping,Pei, Shijin,Liu, Yanli,&Chen, Yulin.(2009).Study on the frequency-scan quadrupole ion trap mass spectrometry.Guangxue Xuebao/Acta Optica Sinica,29(SUPPL.),223-225. |
MLA | Cui, Fenping,et al."Study on the frequency-scan quadrupole ion trap mass spectrometry".Guangxue Xuebao/Acta Optica Sinica 29.SUPPL.(2009):223-225. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论