Influence of the Impeller/Guide Vane Clearance Ratio on the Performances of a Nuclear Reactor Coolant Pump | |
Cheng, Xiaorui1,2![]() ![]() | |
2022 | |
发表期刊 | FDMP-FLUID DYNAMICS & MATERIALS PROCESSING
![]() |
ISSN | 1555-256X |
卷号 | 18期号:1页码:93-107 |
摘要 | An AP1000 nuclear reactor coolant pump is considered to assess the influence of the Impeller/Guide vane clearance on the performances of this type of pumps. Experiments and numerical simulations relying on an unidirectional fluid-solid coupling approach are used to investigate the problem (stress, strain and mode of the rotor). The results reveal the relationship existing between the hydraulic performance of the nuclear reactor coolant pump and the clearance ratio. The effect of clearance ratio on the maximum equivalent stress on the back surface of the impeller blade is greater than that on the working surface (the maximum equivalent stress on the back surface of impeller blade is about three times that on the working surface). The clearance ratio has a scarce effect on the first six natural frequencies of the rotor of the nuclear reactor coolant pump. The related vibrational modes have different waveforms. |
关键词 | Nuclear reactor coolant pump clearance ratio fluid-solid coupling stress and strain numerical calculation |
DOI | 10.32604/fdmp.2022.017566 |
收录类别 | ESCI ; EI |
语种 | 英语 |
WOS研究方向 | Materials Science |
WOS类目 | Materials Science, Multidisciplinary |
WOS记录号 | WOS:000718810400008 |
出版者 | TECH SCIENCE PRESS |
EI入藏号 | 20215011327134 |
EI主题词 | Impellers |
EI分类号 | 601.2 Machine Components ; 618.2 Pumps ; 803 Chemical Agents and Basic Industrial Chemicals |
来源库 | WOS |
引用统计 | 无
|
文献类型 | 期刊论文 |
条目标识符 | https://ir.lut.edu.cn/handle/2XXMBERH/155615 |
专题 | 能源与动力工程学院 体育教学研究部 |
通讯作者 | Cheng, Xiaorui |
作者单位 | 1.Lanzhou Univ Technol, Coll Energy & Power Engn, Lanzhou 730050, Peoples R China; 2.Key Lab Fluid Machinery & Syst Gansu Prov, Lanzhou 730050, Peoples R China |
第一作者单位 | 能源与动力工程学院 |
通讯作者单位 | 能源与动力工程学院 |
第一作者的第一单位 | 能源与动力工程学院 |
推荐引用方式 GB/T 7714 | Cheng, Xiaorui,Liu, Xiang,Lv, Boru. Influence of the Impeller/Guide Vane Clearance Ratio on the Performances of a Nuclear Reactor Coolant Pump[J]. FDMP-FLUID DYNAMICS & MATERIALS PROCESSING,2022,18(1):93-107. |
APA | Cheng, Xiaorui,Liu, Xiang,&Lv, Boru.(2022).Influence of the Impeller/Guide Vane Clearance Ratio on the Performances of a Nuclear Reactor Coolant Pump.FDMP-FLUID DYNAMICS & MATERIALS PROCESSING,18(1),93-107. |
MLA | Cheng, Xiaorui,et al."Influence of the Impeller/Guide Vane Clearance Ratio on the Performances of a Nuclear Reactor Coolant Pump".FDMP-FLUID DYNAMICS & MATERIALS PROCESSING 18.1(2022):93-107. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Cheng-2022-Influence(3035KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论