Calculation of pipe water hammer pressure with liquid column separation by improved two-fluid model
Fu, You1; Jiang, Jin2; Li, Yanhui2; Yin, Rui2
2018-08-01
发表期刊Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering
ISSN10026819
卷号34期号:15页码:58-65
摘要In this paper, we improved an existed two-fluid model for simulating the transient flow with liquid-column separation in the pipeline system. An improved NND numerical algorithm was proposed to ensure the accuracy and stability of the model. The finite relaxation and the infinite relaxation methods were compared. It was concluded that when using the finite relaxation calculation method, the relaxation coefficient was too large, resulting in the reverse correction for vapor-liquid phase pressure difference in the equation, which would cause the interruption of calculation. When the calculation method of the infinite relaxation coefficient was used, a stable calculation could be performed without setting the initial concentration of the foam particles, whilst the transient phenomenon could be described more accurately with increasing intensity. In the meantime, due to the forced correction of the void fraction and internal energy distribution after each time step, the method would often produce a larger void fraction and void fraction residue. The water hammer transient tests in two different laboratories were compared to verify the accuracy and applicability of the improved gas-liquid two-phase two-fluid model. We found that for the calculation using the finite relaxation parameters, the phase changes due to cavitation needed to be considered, and also needed to select reasonable bubble concentration to ensure the accuracy of calculation. For the calculation using infinite relaxation parameters, the cavitation model can be neglected, but the model could be used to directly analyze the phenomenon of liquid column separation caused by water hammer phenomenon. As the infinite pressure relaxation calculation method was a kind of mandatory correction calculation method, after each time step, it was considered that the gas phase and the liquid phase pressure reached the equilibrium state, and in fact, the relaxation time of the pressure was usually 1 ms. If the calculation time step was less than 1 ms, due to the forced correction of the calculation method, the two-phase flow in the unbalanced state was forced to be in equilibrium, which led to the correction of the void volume became too large, making reduction of the cavitation model in the low pressure area. The use of improved two-fluid gas-liquid two-phase flow calculation model with a reasonable numerical calculation method and infinite relaxation parameters can be used to predict the transient phenomenon of gas-liquid two-phase pipelines with obvious liquid column separation. The method had high calculation accuracy and it was suitable for water hammer protection in industrial pipelines calculation with a better value of application. © 2018, Editorial Department of the Transactions of the Chinese Society of Agricultural Engineering. All right reserved.
关键词Cavitation Liquids Models Numerical methods Pipelines Pressure Transition flow Void fraction Water hammer Gas liquid two-phase flows Liquid columns Numerical calculation methods Relaxation coefficients Transient flow Water hammer phenomenon Water hammer pressure Water hammer protections
DOI10.11975/j.issn.1002-6819.2018.15.008
收录类别EI
语种中文
出版者Chinese Society of Agricultural Engineering
EI入藏号20184506039285
EI主题词Two phase flow
EI分类号619.1 Pipe, Piping and Pipelines - 631.1 Fluid Flow, General - 631.1.1 Liquid Dynamics - 632.2 Hydraulic Equipment and Machinery - 921.6 Numerical Methods - 931.1 Mechanics - 951 Materials Science
来源库Compendex
分类代码619.1 Pipe, Piping and Pipelines - 631.1 Fluid Flow, General - 631.1.1 Liquid Dynamics - 632.2 Hydraulic Equipment and Machinery - 921.6 Numerical Methods - 931.1 Mechanics - 951 Materials Science
引用统计
文献类型期刊论文
条目标识符https://ir.lut.edu.cn/handle/2XXMBERH/114482
专题新能源学院
能源与动力工程学院
作者单位1.School of Energy and Power Engineering, Lanzhou University of Technology, Lanzhou; 730050, China;
2.Key Lab of Hydraulic Machinery Transients, MOE, Wuhan University, Wuhan; 430072, China
第一作者单位新能源学院
第一作者的第一单位新能源学院
推荐引用方式
GB/T 7714
Fu, You,Jiang, Jin,Li, Yanhui,et al. Calculation of pipe water hammer pressure with liquid column separation by improved two-fluid model[J]. Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering,2018,34(15):58-65.
APA Fu, You,Jiang, Jin,Li, Yanhui,&Yin, Rui.(2018).Calculation of pipe water hammer pressure with liquid column separation by improved two-fluid model.Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering,34(15),58-65.
MLA Fu, You,et al."Calculation of pipe water hammer pressure with liquid column separation by improved two-fluid model".Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering 34.15(2018):58-65.
条目包含的文件
条目无相关文件。
个性服务
查看访问统计
谷歌学术
谷歌学术中相似的文章
[Fu, You]的文章
[Jiang, Jin]的文章
[Li, Yanhui]的文章
百度学术
百度学术中相似的文章
[Fu, You]的文章
[Jiang, Jin]的文章
[Li, Yanhui]的文章
必应学术
必应学术中相似的文章
[Fu, You]的文章
[Jiang, Jin]的文章
[Li, Yanhui]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。