摘要 | The employment of thermal energy storage (TES) system is helpful for the combined heat and power units to enhance the power load regulation capability. The energy storage density of conventional water TES tank will increase substantially when phase change material is involved. Paraffin wax is selected as PCM to fill the capsules and arranged as packed-bed inside the TES tank. The performance of repetitive charging/discharging cycles is investigated experimentally. Working conditions with different switching temperatures and flow rates are discussed to analyze their impact on the charging/discharging duration, temperature distribution and utilization rate. Results indicate that cyclic charging/discharging operation will reach stable and repetitive state after some cycles and such behavior is influenced by the switching temperatures. Increasing flow rate is able to reduce the time spent on reaching stable state while it will also lead to the decline of utilization rate. © 2019, Science Press. All right reserved. |
关键词 | Heat storage Latent heat Packed beds Phase change materials Stream flow Tanks (containers) Temperature distribution Charging/discharging Combined heat and power units Cyclic performance Energy storage density Operational performance Single-tank Switching temperatures Utilization rates |
收录类别 | EI |
语种 | 中文 |
出版者 | Science Press |
EI入藏号 | 20195007823722 |
EI主题词 | Storage (materials) |
EI分类号 | 407.2 Waterways - 619.2 Tanks - 641.1 Thermodynamics - 694.4 Storage - 802.1 Chemical Plants and Equipment |
来源库 | Compendex |
分类代码 | 407.2 Waterways - 619.2 Tanks - 641.1 Thermodynamics - 694.4 Storage - 802.1 Chemical Plants and Equipment |
文献类型 | 期刊论文 |
条目标识符 | https://ir.lut.edu.cn/handle/2XXMBERH/114262 |
专题 | 兰州理工大学 能源与动力工程学院 新能源学院 |
作者单位 | 1.Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, North China Electric Power University, Ministry of Education, Beijing; 102206, China; 2.School of Energy and Power Engineering, Lanzhou University of Technology, Lanzhou; 730050, China |
推荐引用方式 GB/T 7714 | He, Zhao-Yu,Du, Xiao-Ze,Xu, Chao. Experiments on the Combined Cycle Operational Performance of Thermocline Heat Storage With Phase Change Material Packed-bed[J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics,2019,40(11):2658-2663. |
APA | He, Zhao-Yu,Du, Xiao-Ze,&Xu, Chao.(2019).Experiments on the Combined Cycle Operational Performance of Thermocline Heat Storage With Phase Change Material Packed-bed.Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics,40(11),2658-2663. |
MLA | He, Zhao-Yu,et al."Experiments on the Combined Cycle Operational Performance of Thermocline Heat Storage With Phase Change Material Packed-bed".Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics 40.11(2019):2658-2663. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论